Department of energy doe and the international energy conservation code iecc.
Wisconsin attic insulation code.
The ideal attic insulation r value is different than the ideal wall insulation r value.
This map shows thermal recommended levels of insulation for various climate zones based on recommendations from the u s.
Make sure your home is properly insulated in all these locations.
However there is an exception.
Insulation ratings can be improved by adding more layers of insulation.
The table below shows what levels of insulation are cost effective for different climates and locations in the home.
R 38 shall be deemed to satisfy the requirement for r 49 wherever the full height of uncompressed r 38 insulation extends over the wall top plate at the eaves.
B an attic access cover shall be weatherstripped and insulated to a level equivalent to the insulation on the surrounding surfaces when the attic is an unconditioned space.
Comcheck is federal department of energy doe software approved in wisconsin for demonstrating compliance with commercial building envelope requirements and interior exterior general lighting requirements only hvac portions of the program are not acceptable.
Find your zone on the map and then use the chart to determine the level of insulation you need to properly insulate your attic walls floors and crawlspaces.
Achieving greater r values in attics.
The 2015 irc requires r 49 insulation for ceilings with attic spaces.
You should select a loose fill r 49 insulation product.
You can mix the type and material of insulation too.
Duct insulation supply and return ducts in unconditioned space insulated to a minimum of r 8 hot water pipe insulation heating pipe in unheated spaces shall be insulated with a minimum of r 4.
R value is a measure of insulation s ability to resist heat traveling through it.
An unheated and unfinished attic space in wisconsin needs insulation rated between r 49 and r 60.
Sps 322 01 3 b b the vapor retarder requirements under s.
Comcheck can be used for commercial buildings or high rise 3 stories multi family buildings.
The higher the r value the better the thermal performance of the insulation.
Recommended levels of insulation.
Sps 322 39 apply to any dwelling with insulation installed whether or not the insulation is required under this code.
The iecc is the model building code for the united states.
A r 38 will satisfy the ceiling r value requirement for a dwelling where the full height of uncompressed r 38 insulation extends over the wall top plate at the eaves.
All of the referenced codes listed below were adopted in the mid to late.
Pa302 1 ceilings with attic spaces n1102 2 1 r402 2 1.
The first state building code in wisconsin was established in 1914.
Sps 322 38 do not apply to an unheated space such as an attached unheated garage.